Dielectric strength describes an insulating material’s resistance to electrical breakdown under specified test conditions. It helps buyers compare electrical insulation, but the number only becomes useful when the units, thickness and test method are clear.
When selecting Nomex tape, NKN laminate or another insulating tape or film, start with the exact construction. A backing material’s data does not automatically describe the finished adhesive tape or multilayer laminate.
Three electrical terms to keep separate
Breakdown voltage
The voltage at which a tested specimen breaks down electrically. Usually expressed in volts (V) or kilovolts (kV).
Dielectric strength
Breakdown voltage expressed per unit of specimen thickness, such as V/mil or kV/mm, under the stated test conditions.
Working voltage
The operating voltage specified for an application or validated insulation design. A breakdown test result alone does not establish it.
How to read V, kV and V/mil
One kilovolt equals 1,000 volts. One mil is one thousandth of an inch: 0.001 in, or 0.0254 mm. A mil is different from a millimetre.
Hypothetical calculation: if a tested 3 mil specimen breaks down at 6,000 V, the calculated dielectric strength is 6,000 ÷ 3 = 2,000 V/mil. This example illustrates the units; it is not a CGS product rating or a prediction for a different thickness.
How is dielectric strength measured?
A laboratory applies voltage to a prepared specimen using a defined method and records electrical breakdown. Electrode configuration, voltage application and specimen conditioning form part of the test. Intertek’s dielectric-strength testing overview explains the relationship between breakdown voltage, thickness and test conditions.
ASTM D149 and IEC 60243 are commonly referenced for insulating materials. ASTM D1000 covers test methods for pressure-sensitive adhesive-coated tapes used in electrical and electronic applications. Ask which method applies to the particular product and property being quoted.
For a meaningful comparison, request the test method, AC or DC conditions, specimen thickness, conditioning temperature and humidity, and whether the result is typical or a minimum. Also check whether a figure describes breakdown or a specified withstand test.
Which CGS products belong in the comparison?
Several CGS product families can enter an electrical-insulation review. This table identifies selection questions rather than ranking products by a single voltage figure.
| Product family | Where it may fit | What to confirm |
|---|---|---|
| Nomex tape with acrylic adhesive | Insulation holding, coil wrapping and lead bundling. | Backing versus total thickness, finished-tape electrical data, adhesive and thermal class. |
| NKN Nomex–Kapton–Nomex laminate | Motor and generator slot liners, phase insulation and converted parts. | Layer arrangement, total thickness, folded and unfolded properties, and finished-part requirements. |
| Polyimide tape | Electrical insulation and assembly processes requiring a thin film backing. | Adhesive type, backing thickness, total thickness and exact grade. |
| Polyimide film | Film insulation and components where an adhesive-free material is required. | Film grade, thickness, electrical data and conversion requirements. |
| Polyester tape | Applications calling for a polyester film backing and an appropriate adhesive. | Electrical suitability of the selected grade, temperature exposure and adhesive compatibility. |
| Glass cloth tape | Coil or harness wrapping where woven reinforcement is useful. | Adhesive, conformability, varnish compatibility and finished-tape electrical properties. |
| Skived PTFE tape | Projects combining PTFE surface characteristics with specified insulation requirements. | Exact backing and adhesive construction, thickness and grade-specific electrical data. |
Additional requirements can change the shortlist. CGS also offers corona-resistant polyimide film and thermally conductive polyimide film. Review partial-discharge exposure or heat-transfer needs separately from dielectric strength. Conductive and ESD grades also require their own review; they should not be treated as interchangeable with standard insulating grades.
Evaluate the complete insulation system
Short-term breakdown performance does not establish long-term service life. DuPont’s Nomex 410 technical overview distinguishes short-term electrical strength from long-term electrical behaviour and explains that properties vary with paper thickness and density.
Thermal class is another separate consideration. UL’s electrical insulation systems guidance describes evaluating combinations of materials for compatibility at specified temperatures. Review the tape or laminate alongside the winding wire, varnish, resin and other materials in the intended assembly.
Frequently asked questions
What is a good dielectric strength?
There is no single target for every application. Select against the electrical, thermal and mechanical requirements of the design, then compare data obtained under comparable conditions.
Can I calculate breakdown voltage from V/mil?
Multiplication gives an arithmetic value, but it does not validate a different thickness, adhesive or layer arrangement. Request test data for the actual construction rather than assuming that breakdown voltage scales directly with thickness.
Is dielectric strength the same as insulation resistance?
No. Dielectric strength concerns electrical breakdown. Insulation resistance describes resistance to current leakage under specified conditions. Check each property and its units separately.
Can Nomex paper data be used for Nomex adhesive tape?
Use technical information for the finished tape. Adding adhesive or combining paper with other layers changes the construction being evaluated, so the paper data alone is insufficient.
Request technical data for your application
Send CGS the material or construction you are considering, nominal thickness in mil, required voltage or test standard, operating conditions, finished dimensions and quantity. Include any insulation-system or approval requirements.
CGS can also review slitting, sheeting and die-cutting requirements. Other NKN layer constructions can be custom made for review against your requirements.
Discuss your application Request technical data by email
This guide explains how to read specifications. Product selection should use current data for the exact grade and construction, together with the requirements of the intended assembly.